Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system WARNING: This system is for use on water supplies that have been treated to public water systems Standards This system has been tested to demonstrate effective reduction of microcystins, however, in the event of reported cyanotoxin event in your water supply, other cyanotoxins may be present in the drinking water which may not be effectively reduced by this system In the event of cyanotoxin notification, follow the recommendations of your drinking water authority The compounds certified under NSF/ANSI 401 have been deemed as incidental contaminants/emerging compounds Incidental contaminants are those compounds that have been detected in drinking water supplies at trace levels While occurring at only trace levels, these compounds can affect the public acceptance/perception of drinking water quality The estimated replacement time of filter, which is consumable part, is not an indication of quality guarantee period, but it means the ideal time of filter replacement Accordingly, the estimated time of filter replacement may be shortened in case it is used in an area of poor water quality The filtration device installation shall comply with applicable state and local regulations The reverse osmosis system contains replaceable treatment component, critical for the effective reduction of total dissolved solids and that product water shall be tested periodically to verify that the system is performing properly The influent water to the system shall include the following characteristics: No organic solvents Chlorine: 2 ppm pH: 7 - 8 Temperature: 41 ºF 95 ºF(5 ºC 35 ºC) Iron: 2 mg/L Turbidity: 1 NTU Hardness: 1000 mg/L This system has been tested for the treatment of water containing pentavalent arsenic (also know as As(V), As(+5), or arsenate) at concentrations of 050 mg/L or less This system reduces pentavalent arsenic, but may not remove other forms of arsenic This system is to be used on water supplies containing detectable free chlorine residual at the system inlet or on water supplies that have been demonstrated to contain only pentavalent arsenic Treatment with chloramines (combined chlorine) is not sufficient to ensure complete conversion of trivalent arsenic to pentavalent arsenic Please see the Arsenic Facts section of this Performance Data Sheet for further information Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts Efficiency rating means the percentage of the influent water to the system that is available to the user as reverse osmosis treated water under operating conditions that approximate typical daily usage Refer to the owner manual for specific installation instructions, manufacturer limited warranty, user responsibility, and parts and service availability For parts and service availability, please contact your local dealer or Coway Model of Filter Type Usable period (Months) CNFN8S NEO-SENSE FILTER 6 CRMFN8S-20-N2 RO MEMBRANE FILTER 20 CIFN8S-PLUS PLUS INNOSENSE FILTER 18 ARSENIC FACTS Arsenic (abbreviated As) is found naturally in some well water Arsenic in water has no color, taste or odor It must be measured by lab test Public water utilities must have their water tested for arsenic You can get the results from your water utility If you have your own well, you can have the water tested The local health department or the state environmental health agency can provide list of certified labs The cost is typically $15 to $30 Information about arsenic in water can be found on the Internet at the US Environmental Protection Agency website: epa gov/safewater/arsenic html There are two forms of arsenic: pentavalent arsenic (also called As(V), As(+5), and arsenate) and trivalent arsenic (also called As(III), As(+3), and arsenite) In well water, arsenic may be pentavalent, trivalent, or combination of both Special sampling procedures are needed for lab to determine what type and how much of each type of arsenic is in the water Check with the labs in your area to see if they can provide this type of service Reverse osmosis (RO) water treatment systems do not remove trivalent arsenic from water very well RO systems are very effective at removing pentavalent arsenic free chlorine residual will rapidly convert trivalent arsenic to pentavalent arsenic Other water treatment chemicals such as ozone and potassium permanganate will also change trivalent arsenic to pentavalent arsenic combined chlorine residual (also called chloramine) may not convert all the trivalent arsenic If you get your water from public water utility, contact the utility to find out if free chlorine or combined chlorine is used in the water system This system is designed to remove pentavalent arsenic It will not convert trivalent arsenic to pentavalent arsenic The system was tested in lab Under those conditions, the system reduced 050 mg/L pentavalent arsenic to 010 mg/L (ppm) (the USEPA standard for drinking water) or less The performance of the system may be different at your installation Have the treated water tested for arsenic to check if the system is working properly The RO component of system must be replaced every 20 months to ensure the system will continue to remove pentavalent arsenic The component identification and locations where you can purchase the component are listed in the installation/operation manual
페이지 42
Chemical Drinking water regulatory level1 (MCL/MAC) mg/L Influent challenge concentration2 mg/L Chemical reduction percent Maximum product water concentration mg/L alachlor 002 050 98 0013 atrazine 003 100 97 0033 benzene 005 081 99 0013 carbofuran 04 190 99 0013 carbon tetrachloride 005 078 98 00184 chlorobenzene 077 99 0013 chloropicrin - 015 99 00023 2,4-D 07 110 98 00174 dibromochloropropane(DBCP) 0002 052 99 000023 o-dichlorobenzene 080 99 0013 p-dichlorobenzene 075 040 98 0013 1,2-dichloroethane 005 088 955 00485 1,1-dichloroethylene 007 083 99 0013 cis-1,2-dichloroethylene 07 170 99 00053 trans-1,2-dichloroethylene 086 99 0013 1,2-dichloropropane 005 080 99 0013 cis-1,3-dichloropropylene - 079 99 0013 dinoseb 007 170 99 00024 endrin 002 053 99 000594 ethylbenzene 088 99 0013 ethylene dilbromide (EDB) 00005 044 99 000023 haloacetonitriles (HAN) bromochloroacetonitrile dibromoacetonitrile dichloroacetonitrile trichloroacetoritrile - - 022 024 0096 015 98 98 00053 00063 00023 00033 haloketones (HK): 1,1-dichloro-2-propanone 1,1,1-trichloro-2-propanone - - 0072 0082 99 96 00013 00033 heptachlor (H-34,Heptox) 0004 08 99 0004 heptachlor epoxide 0002 01076 98 00026 hexachlorobutadiene - 044 98 0013 hexachlorocyclopentadiene 05 060 99 0000023 lindane 0002 055 99 000013 methoxychlor 04 050 99 00013 pentachlorophenol 001 096 99 0013 simazine 004 120 97 0043 styrene 150 99 00053 1,1,2,2-tetrachloroethane - 081 99 0013 tetrachloroethylene 005 081 99 0013 toluene 1 078 99 0013 2,4,5-TP (silvex) 05 270 99 00164 tribromoacetic acid - 042 98 0013 1,2,4-trichlorobenzene 07 160 99 00053 1,1,1-trichloroethane 084 95 00464 1,1,2-trichloroethane 005 150 99 00053 trichloroethylene 005 180 99 00103 trihalomethanes (includes): chloroform (surrogate chemical) bromoform bromodichloromethane chlorodibromomethane 080 300 95 015 xylenes (total) 10 070 99 0013 1 These harmonized values were agreed upon by representatives of USEPA and Health Canada for the purpose of evaluating products to the requirements of this Standard 2 Influent challenge levels are average influent concentrations determined in surrogate qualification testing 3 Maximum product water level was not observed but was set at the detection limit of the analysis 4 Maximum product water level is set at value determined in surrogate qualification testing 5 Chemical reduction percent and maximum product water level calculated at chloroform 95% breakthrough point as determined in surrogate qualification testing 6 The surrogate test results for heptachlor epoxide demonstrated 98 reduction These data were used to calculate an upper occurrence concentration which would produce maximum product water level at the MCL COWAY Co Ltd 136-23, Yugumagoksa-ro, Yugu-eup, Gongju-si, Chungcheongnam-do, 32508 Korea Tel